INTU FR GRILLE
INTU FR COLLAR
March 27, 2017
INTU FR EJ SEAL
March 16, 2018
Show all
INTU_FR_GRILLE_set2_2021_500

INTU FR GRILLE

  • fire resistance: 60, 120 and 240 minutes
  • air flow up to 80%
  • maximum dimensions:
    single round grille – Ø 400 [mm];
    single rectangular grille – 600 x 600 [mm]

 

Firestop ventilation grilles INTU FR GRILLE are made of a rigid steel frame with an intumescent insert. During a fire, the intumescent insert expands prevent the spread of fire and hot gases, ensuring the partition maintains fire resistance class up to EI 240.

 

INTU FR GRILLE TDS EN

INTU FR GRILLE TECHNICAL ASSESSMENT EN

INTU FR GRILLE DOP EN

INTU FR GRILLE C50/C80 SDS EN

INTU FR GRILLE R40A/R80 SDS EN

INTU FR GRILLE R40B SDS EN

 

Category:

Where to use

INTU FR GRILLE is install in the ventilation holes in walls and floors. The material is swelling during fire fills the hole completely.

Rigid wall:

The wall must be minimum thickness 150 mm.
Must have concrete, cellular concrete or masonry
structure, with minimum density 600kg/m3.

Rigid floor:

The floor must be minimum thickness 150 mm. Must have concrete, cellular concrete or masonry structure, with minimum density 1700kg/m3.

 

APPLICATION CONDITIONS:

Maximum ambient temperature:

  • round grille C50, C80 – 70 ºC
  • rectangular grille R40A – 70 ºC
  • rectangular grille R40B – 40 ºC
  • rectangular grille R80 – 70 ºC

Compliance

Compilance:

  • TDS
  • Technical Assessment:
    00518/25/Z00NZP of 14/01/2025
  • Declaration of Performance:
    DoP 2/2025
  • SDS

Availability

round grille C50, C80 – Ø100 ÷ Ø400
rectangular grille R40A – 100 x 100 ÷ 600 x 600
rectangular grille R40B – 100 x 100 ÷ 300 x 300
rectangular grille R80 – 100 x 100 ÷ 600 x 600

INTU FR GRILLE grilles for type R40A and R80, can be made in non-standard dimensions.

Installation

1. Adjust the size of the grille to the size of the hole.
2. Apply a small amount of intumescent acrylic mastic (e.g. INTU FR MASTIC to the grille along its edge.)
3. Push the grille into the hole.
4. Fill the remaining gaps and cavities with firestop acrylic putty.
5. Install masking plates (e.g. INTU ATP) on both sides of the partition using steel screws.

 

Transport & storage

Store in dry and cool conditions at temperatures
between + 5°C and + 35°C.

 

 